Quantitative determination of wine polysaccharides by gas chromatography-mass spectrometry (GC-MSD) and size exclusion chromatography (SEC)

  1. Guadalupe, Z. 13
  2. Martínez-Pinilla, O. 1
  3. Garrido, A. 3
  4. Carrillo, J.D. 2
  5. Ayestarán, B. 13
  1. 1 Universidad de La Rioja
    info

    Universidad de La Rioja

    Logroño, España

    ROR https://ror.org/0553yr311

  2. 2 Excell Ibérica, C/Planillo 12, 26006 Logroño, La Rioja, Spain
  3. 3 Instituto de Ciencias de la Vid y del Vino
    info

    Instituto de Ciencias de la Vid y del Vino

    Logroño, España

    ROR https://ror.org/01rm2sw78

Revista:
Food Chemistry

ISSN: 0308-8146

Año de publicación: 2012

Volumen: 131

Número: 1

Páginas: 367-374

Tipo: Artículo

beta Ver similares en nube de resultados
DOI: 10.1016/J.FOODCHEM.2011.08.049 SCOPUS: 2-s2.0-80054044488 WoS: WOS:000296826400051 GOOGLE SCHOLAR

Otras publicaciones en: Food Chemistry

Repositorio institucional: lock_openAcceso abierto Postprint lockAcceso abierto Editor

Resumen

Wine polysaccharides play an important role on a number of technological and quality properties of wines and thus several methods have been proposed for their quantification. The present study evaluates the suitability of gas chromatography with mass spectrometry detector (GC-MS) for determining the content of wine monosaccharides and thus polysaccharide families. Factors affecting the yield of polysaccharide precipitation were firstly evaluated and the GC-MS method was characterised and compared with the previously reported GC-FID method. Repeatability and reproducibility values were similar in both methods, with values ranging from 1% to 14%. LODs obtained by MS were below 1.0 μg for all monosaccharides and LOQs were below 1.8 μg. Moreover, a recovery study of the whole method was carried out and it provided absolute recoveries between 81% and 116% for different wine samples, very good values taking into account the multi-step procedure. Both GC-MS and GC-FID were applied to determine the content of wine polysaccharide families in three wine samples and no significant differences were observed. Finally, high-resolution size exclusion chromatography with refractive index detector (HRSEC-RID) was applied to obtain the molecular weight distributions of the wine polysaccharides and to estimate their global content. The correlation observed between the polysaccharide values obtained with the GC method and the HRSEC-RID method (r = 0.746, p < 0.05) indicated that the latter could serve as a rapid and simple method to give an estimation of total wine polysaccharides although it can not be used to quantify in a precise way. © 2011 Elsevier Ltd. All rights reserved.