Simultaneous determination of sulphide and sulphite by GPMAS. Comparative study of different calculation methods
- Pinillos, S.C. 1
- Vicente, I.S. 1
- Asensio, J.S. 1
- Galbán^Bernal, J. 2
-
1
Universidad de La Rioja
info
-
2
Universidad de Zaragoza
info
ISSN: 0039-9140
Año de publicación: 1995
Volumen: 42
Número: 7
Páginas: 937-943
Tipo: Artículo
beta Ver similares en nube de resultadosOtras publicaciones en: Talanta (Oxford)
Resumen
A method for the simultaneous determination of sulphide and sulphite is described, which involves continuous H 2S and SO 2 generation, preconcentration in a liquid nitrogen trap and measurement of the molecular absorption spectra of volatiles in the gas phase in 190-220 nm range. Under the recommended conditions (sample flow: 50 ml/min and concentrated sulphuric acid flow: 12 ml/min; generation time: 4 min) linear response ranges from 0.05 μg/ml for S 2- and 0.20 μg/ml SO 2- 3 are obtained with detection limits of 0.05 and 0.20 μg/ml respectively. Synthetic mixtures of the two components have been solved and a comparative study of different calculation methods has been made. In conclusion, multiwavelength methods offer better precision and accuracy. © 1995.